more info Specialized Applications

 

Enclosures protected by gaseous fire suppression systems should tested for air-tightness upon commissioning of the system and annually thereafter. This is critical to ensure that the system will work effectively when activated; too much air-leakage will result in the concentration of the fire suppressant agent falling too quickly.  

Air Pressure Testing provide the necessary Room Integrity Testing to the required NFPA 2001 or ISO 14520 methodologies.  

We have extensive experience in testing all types and sizes of enclosure, from server rooms in offices to hospital intensive care units . In each case we carry out the necessary volumetric calculations prior to the test and use calibrated Retrotec test fan systems along with laptops running Retrotec CA2001 software to determine results immediately upon completion of test.  

In the event of a failed test result, we will locate and record the air leakage sites using smoke-puffers if permitted. We subsequently provide full reports, incorporating all necessary data test information and certification, usually within a few days of the test. This will ensure that you have all of the required information to undertake accurate remeadial works. 

Fire Integrity Testing 
Air Pressure Testing can provide the necessary Room Integrity Testing to the required NFPA 2001 or ISO 14520 methodologies. We have extensive experience in testing all types and sizes of enclosure, from server rooms in offices to hospital intensive care units. In each case we carry out the necessary volumetric calculations prior to the test and use calibrated test fan systems along with laptops running complaint CA2001 software to determine results immediately upon completion of test. 

Our company believes in working with our clients to achieve the best possible results for an test. We believe that by being involved at the beginning of a project we can save our clients expensive and difficult remedial works at the completion stage of a project. 
  
  

 

| fire protection enclosure testing | integrity enclosure testing | total flooding clean agent enclosure |
| enclosure integrity testing | fire enclosure integrity testing | fire risk assessment |

 

     
Company
References
Services
Contact Us
Blower Door Systems
Gauges
Fans
Accessories
Gielle Srl - Administrative Headsquares 
Via R. Ferri 32 Z.I. - 70022 Altamura (Ba) Italy
Tel +39 0803118998 - Fax + 39 0803101309
E-mail:
info@doorfantest.com - Save in outlook
© 2008 Gielle Srl. All rights reserved. P.IVA 05157680728. Created by www.omnilink.it